Ventilation and smoke extraction solutions for data centers
Ventilation / Articles / Smoke Extraction / Ventilation with motorised hatch

Ventilation and smoke extraction solutions for data centers

The growth of data centers and Battery Energy Storage Systems (BESS) is increasing the requirements for ventilation, energy efficiency and fire safety.

The high concentration of equipment, significant thermal loads and continuous operation of these facilities require solutions capable of maintaining suitable environmental conditions and responding effectively to emergency situations.

SODECA offers ventilation and smoke extraction solutions for data centers, including equipment tested and certified to F400 in accordance with EN 12101-3, systems with motorised dampers and ATEX-certified solutions for applications where potentially explosive atmospheres may occur.

Why is smoke extraction important in data centers?

Smoke extraction in data centers helps limit the spread of smoke and combustion gases in the event of a fire, improve visibility and facilitate the intervention of emergency services.

In these facilities, the high concentration of equipment and critical infrastructure makes smoke one of the main risk factors. Smoke can spread to other areas and compromise the operation of equipment that has not yet been directly affected by the fire.

For this reason, smoke extraction systems must form part of the data center's fire protection strategy and meet the specific characteristics and requirements of each installation.

F400-certified smoke extraction solutions for data centers

F400-certified smoke extraction systems are designed to operate at temperatures of 400 °C for 120 minutes, in accordance with the testing and classification conditions established by EN 12101-3.

SODECA offers ventilation solutions tested and certified to F400 in accordance with EN 12101-3, designed for daily ventilation and smoke extraction in the event of a fire in data centers.

These units meet the requirements of normal facility operation while also contributing to the extraction of smoke and combustion gases when the fire protection system is activated.

SODECA also carries out Computational Fluid Dynamics (CFD) simulations to analyse smoke behaviour and spread in the event of a fire. These simulations make it possible to assess the effectiveness of smoke extraction systems and study their performance according to the specific characteristics of each data center.

CFD simulation of smoke propagation in a data centre during a fire to assess the effectiveness of smoke extraction systems.

What are the advantages of motorised dampers in data centers?

Smoke extraction solutions with motorised dampers combine fire safety with the airtightness and energy efficiency requirements of data centers.

During normal operation, when the smoke extraction system is not activated, the dampers remain closed, reducing air leakage and unwanted heat transfer between the inside and outside of the building.

In the event of a fire, the dampers open automatically to allow smoke and combustion gases to be extracted.

This configuration offers several advantages:

  • Improved airtightness: reduces air leakage and helps maintain suitable indoor environmental conditions.
  • Energy efficiency: limits unwanted heat loss and helps reduce energy consumption associated with the facility's climate control systems.
  • Thermal insulation: helps reduce the risk of condensation and protects the installation against changes in temperature and humidity.
  • Fire safety: enables smoke extraction through the automatic opening of the dampers.

SODECA's solutions with motorised dampers therefore meet both the fire protection and energy efficiency requirements of data centers.

Illustration of a data centre with SODECA F400-certified smoke extraction systems, motorised dampers, airtightness, thermal insulation and energy efficiency.

Ventilation in BESS and areas at risk of gas accumulation

Battery Energy Storage Systems (BESS) and Uninterruptible Power Supply (UPS) systems may present risks associated with the generation and accumulation of flammable gases, depending on the technology used and the operating conditions.

Image 3 – Battery Systems (UPS and BESS)  ALT text: Infographic showing hydrogen release risks from lead-acid batteries and thermal runaway risks in lithium-ion batteries used in UPS and BESS energy storage systems.

Lead-acid batteries, for example, may release hydrogen during charging or as a result of a malfunction. Lithium-ion batteries, on the other hand, may release flammable and toxic gases in the event of thermal runaway, increasing the risk of fire and, under certain circumstances, explosion.

In these areas, adequate ventilation is essential to ensure effective air renewal and prevent gases from accumulating at hazardous concentrations.

When a risk assessment identifies the potential formation of an explosive atmosphere, ventilation equipment must be selected according to the hazardous area classification and the applicable safety requirements.

ATEX ventilation solutions for potentially explosive atmospheres

ATEX ventilation solutions are designed for applications where there is a risk of explosive atmospheres forming due to the presence of flammable gases or substances.

For these installations, SODECA offers ATEX-certified ventilation solutions in accordance with EN 14986:2017 and Directive 2014/34/EU, with equipment suitable for Zone 1 (Category 2), subject to the conditions specified in its certification.

These systems allow ventilation to be integrated into the safety measures established for areas at risk of flammable gas accumulation, such as certain battery energy storage facilities.

Equipment selection must take into account the characteristics of each installation, the hazardous area classification and the applicable technical and regulatory requirements.

Ventilation solutions tailored to the requirements of each data center

Ventilation, smoke extraction and the prevention of risks associated with gas accumulation are essential aspects of the safety and operation of data centers and energy storage facilities.

SODECA offers solutions tailored to these requirements, ranging from F400-certified equipment in accordance with EN 12101-3 for smoke extraction to systems with motorised dampers and ATEX solutions for potentially explosive atmospheres.

These technologies, together with CFD simulation analysis, help address different safety, airtightness and energy efficiency requirements, contributing to the protection of critical infrastructure and the maintenance of suitable operating conditions.