Ventilation solutions


Hatch Fans
In-line Duct Fans
Axial Fans
Centrifugal Fans
Smoke Extract Fans 400 ºC/2h - 300 ºC/2h
Pressurisation Systems for Staircases, Lobbies and Evacuation Routes
Explosive Atmospheres ATEX fans
Fans for Ovens
Fans for Industrial Applications
Roof Fans
EC Technology and Efficient Fans
Indoor Air Treatment Solutions
Ventilation for Houses
Air Curtains
Accessories

Accessories


BOXPARK
Control panels for car park ventilation systems with triple purpose: daily ventilation, CO concentration control and smoke extraction in case of fire

Control panels in metal enclosure with all the necessary elements for the management and control of fans in car park ventilation systems, whether they are based on duct networks or impulse fans, for the control of CO concentration levels and smoke extraction in case of fire. Customised panels for all power ratings and number of fans according to project requirements.

BOXPARK BASIC:
• Control panel for smoke extraction in case of fire and CO control in single zone car parks, with daily ventilation mode using a time programmer included.

BOXPARK ADVANCED:
• Control panel for smoke extraction in case of fire and CO control in car parks for single or multiple zones, with daily ventilation mode using a time programmer included, with the possibility of managing motorised dampers and incorporating a remote panel for fire fighters.

BOXPARK ADVANCED PLC:
• Control panel for smoke extraction in case of fire and CO control in car parks for single or multiple zones, with daily ventilation mode using a time programmer included, with the possibility of managing motorised dampers and incorporating a remote panel for fire fighters. Includes PLC with algorithm for managing the activation sequence of the ventilation systems, either by duct networks or by impulse (Jet fan type), in case of fire, with MODBUS communications and WEB SERVER incorporated. All the logic of the system can be adapted to the project on demand.

Generic specifications BOXPARK cabinet on request:
• Power supply: 400 V AC three-phase plus neutral and earth conductor.
• Metal enclosure, depending on the dimensions of the wall-mounted or self-supporting equipment with plinth.
• Load-break disconnector switch sized to the maximum power of the system.
• Natural or forced ventilation of the electrical panel, with thermostat for activation/deactivation and thermomagnetic circuit breaker protection.
• Interior cabinet lighting (from 1600 mm height).
• Auxiliary voltage for 24 V DC control through power supply and protections.
• SCHUKO base inside the control panel (protected).
• Unbalance and phase loss detector.
• Overload and short-circuit protection per group.
• Depending on the drives, the equipment incorporates the following protections:
• Frequency converter starter (VSD): Individual input thermomagnetic circuit breaker.
• Single-speed contactor starter (S1): Individual thermomagnetic circuit breaker per group, individual motor-protective switch.
• Starting by double speed contactor (S2): Individual magnetothermic circuit breaker per group, individual motor protection switch for high speed, individual motor protection switch for slow speed.
• Back-up of the system's electronics by UPS in case of power failure.
• Microcontroller with programmable logic (PLC).
• Communication with BMS, MODBUS TCP protocol.
• WEB SERVER integrated for programming.
• Daily time switch with battery reserve, for activation of daily ventilation per zone.
• Connection input to monoxide control unit with three CO activation levels, low level, high level and alarm level. NO potential-free activation contacts.
• Connection input with fire detection control panel, via NO or NC potential-free activation contact (selectable). Memory of the last operating status and resettable fire activation signal, via key switch on the front of the control panel.
• 0-AUTO-MANUAL selectors per group.
• Control panel status lights per zone (System OK, Fault, Run, CO Activation and Fire Activation).
• Status signals (System OK, Fault, Run, CO Activation and Fire Activation).
• General magneto-thermal and differential line protection.
• Differential protection by group and zone (Jet fans, extraction, supply).
• 2-speed fan control.
• Fan control using a variable speed drive.
• Reversible fans control.
• LC filters (recommended with variable frequency drive (VSD) control from 50 m of EMC cable and from 100 m of non-screened cable).
• Possibility of request for several areas.
• Possibility of analogue CO signal for proportional operation.
• Remote control for firefighters that incorporates 0-AUTO-MANUAL selector, and status lights (System OK, Fault, Run and Fire Activation).
• Touch screen for monitoring and configuration.
• Motorised gate management.
• Interconnection between panels.

Price finder
Search for a product through its name or code and we will show you its price (VAT not included).
    R.R.P. = _.___,__ €